- The event took place on a 3000 HP Land Drilling Rig while running 9 7/8” casing in the 12 ¼” hole section of an unconventional well. Well was vertical.
- Well architecture consists of 20” Surface Casing at 945m, 13 3/8” casing at 3348 m at 12 ¼” hole section at 4794m.
- Run 9 7/8” casing to 4793m.
- After landing casing, circulated 9 7/8” casing, increasing pump rates from 0.70 m3/min to 1.45 m3/min and SPP of 450 kPa.
- At 2000 strokes into bottoms up, returns diverted through the manifold. Maximum gas of 2500 units observed prior to going through MGS.
- Circulate through choke at 1.0 – 1.5 m3/min. Initial casing pressure of 170 kPa and SPP of 570 kPa. Casing pressure spiking at 5800 strokes to 9500 kPa and decreasing to 2100 kPa as bottom up strokes expired.
- Significant amount of gas observed at surface. Approximately 5 m3 of invert drilling fluid was spilled over from open bottom poor boy degasser (MGS) while circulating bottoms up.
- Shut in well & monitored for pressure evaluation.
- Observed increase in SIDPP & SICP.
- Continued to monitor pressure evolution.
- Pressure stabilized at SIDPP 300 kPa & SICP 450 kPa.
- Performed drillers method well kill and stabilized well with mud weight of 1750 kg/m3.
- Well was static prior to bottoms up circulation (some reports noted minor flow when landing mandrel hanger).
- During the bottoms up, returns were diverted to MGS as a precaution for trip gas and because pump pressure was much less than expected.
- The gain was not noticed until the well was circulated once the casing was on bottom.
- The section was drilled with a narrow mud-weight window.
|
Disclaimer
Whilst every effort has been made to ensure the accuracy of the information contained in this publication, neither the IOGP nor any of its members past present or future warrants its accuracy or will, regardless of its or their negligence, assume liability for any foreseeable or unforeseeable use made thereof, which liability is hereby excluded. Consequently, such use is at the recipient's own risk on the basis that any use by the recipient constitutes agreement to the terms of this disclaimer. The recipient is obliged to inform any subsequent recipient of such terms.
This document may provide guidance supplemental to the requirements of local legislation. Nothing herein, however, is intended to replace, amend, supersede or otherwise depart from such requirements. In the event of any conflict or contradiction between the provisions of this document and local legislation, applicable laws shall prevail.
|