Lifeboats - Routine Inspection and Maintenance
|
Country: --- |
Location: --- |
Incident Date: --- Time: --- |
Type of Activity: Transport - Water, incl. marine activity |
Cause: Water related, drowning |
Function: --- |
|
What happened?:
Recent inspections conducted by NOPSA and information provided to NOPSA have raised concerns regarding the general condition of some Totally Enclosed Motor Propelled Survival Craft (TEMPSC) currently in use in the offshore regime. Inspection findings have
resulted in nine enforcement actions on facility operators in the past four months. The enforcement actions focused primarily on the lack of effective routine maintenance and inspections being conducted on facility TEMPSC. TEMPSC were identified with damaged
or broken safety harnesses, unsecured and loose items, and illegible safety and operating instructions. A shortfall in the competencies of personnel assigned to essential lifeboat duties was also noted. NOPSA is particularly concerned that some facilities'
induction processes do not provide personnel with suitable familiarisation of assigned lifeboat locations and procedures. The expectations of and by personnel during preparation for the boarding process, for example, is also not always clearly illustrated
in the induction.
What could go wrong?
For many facilities currently in service, the TEMPSC are the primary source of evacuation from an uncontrolled or escalating major event, while other facilities list the TEMPSC as the secondary means of evacuating personnel. It has been well established
however, that major accident events may not afford the time or the conditions for helicopters to be employed as the primary means of evacuation, leaving TEMPSC as the preferred alternative. Delays in the launching of TEMPSC due to a lack of familiarisation
with location or procedures could be the difference between a successful controlled departure and an uncontrolled abandonment. The ability by personnel to understand and observe boarding arrangements, secure the craft for launch and progress the launching
of the TEMPSC itself are all critical to a successful evacuation. TEMPSC are designed to provide for the protection of personnel in extreme weather conditions and rough seas, however this protection is negated if seat belts or harnesses cannot secure occupants
during adverse movement or roll. Equally, items within the craft should be securely stowed to prevent damage to people or equipment.
|
Corrective Actions and Recommendations: Key lessons:
Operators are encouraged to review their current procedures concerning TEMPSC and ensure that the following issues are suitably addressed:
- Ensure the personnel induction process includes a visit to the assigned lifeboat, an overview of the preparation and boarding procedures and a general familiarisation of
your specific facility's TEMPSC and contents.
- Ensure personnel assigned to lifeboat duties (coxswains, bowmen, etc.) have the required training and competencies to effectively and efficiently board, launch and operate
your specific facility's TEMPSC in all conditions including during the hours of darkness and/or inclement weather.
- Assign accountability and responsibility for TEMPSC maintenance and inspections to a suitable position to ensure ownership of the procedures and processes.
|
|
|
Safety Alert number: 236
IOGP Safety Alerts http://safetyzone.iogp.org/ |
Disclaimer
Whilst every effort has been made to ensure the accuracy of the information contained in this publication, neither the IOGP nor any of its members past present or future warrants its accuracy or will, regardless of its or their negligence, assume liability for any foreseeable or unforeseeable use made thereof, which liability is hereby excluded. Consequently, such use is at the recipient's own risk on the basis that any use by the recipient constitutes agreement to the terms of this disclaimer. The recipient is obliged to inform any subsequent recipient of such terms.
This document may provide guidance supplemental to the requirements of local legislation. Nothing herein, however, is intended to replace, amend, supersede or otherwise depart from such requirements. In the event of any conflict or contradiction between the provisions of this document and local legislation, applicable laws shall prevail.
|